Cyclic test sequence with graduated alarming.

What it is about
Station: Alarm Handling Simulation Category: Automation & sequence control

Shows the SonicTC alarm system bundled into one workflow: an acceleration sensor is measured cyclically, then the noise metrics SNR and SINAD are calculated as characteristics and checked against graduated evaluation limits. Depending on the result the sequence raises either a warning or a critical alarm with dynamic message text. The error flow demonstrates automatic reactions to alarms: restarting the sensor on poor data quality and a PLC warning on high database load.

The sequence in detail

Workflows in detail

  1. Main

    Cyclic test sequence with graduated alarming.

    Start → endless loop (start trigger → acceleration sensor measurement → sensor quality analysis → if "low quality": warning alarm → if "bad quality": critical alarm → store) → end; error flow with a sensor restart loop and a database alarm including a PLC warning output.

  2. Sensor Quality Check

    Characteristic block quantifying the signal quality.

    Characteristic start → SNR → SINAD → characteristic end.

Inside the software

Task tree: endless loop with sensor quality alarms and error tasks
Task tree: endless loop with sensor quality alarms and error tasks
Measurement sequence "Alarm Handling" with workflow graph
Measurement sequence "Alarm Handling" with workflow graph

Take it with you

Import through the SonicTC DbManager — individually or merged into an existing database.