Measure grid, signal trigger & continuous monitoring
Continuous monitoring with grid-based acquisition.
Shows how a measure grid can calculate characteristics during a running measurement and react to them — here across a speed range from 100 to 300 RPM. A signal trigger on the speed sensor starts the acquisition; the measurement data is analysed statistically grid point by grid point (mean value, FFT), and a condition inside the grid detects when the target speed is reached. The screencast shows the visualisation in the test view (HMI/SCADA).
Workflows in detail
-
Main
Continuous monitoring with grid-based acquisition.
Start → endless loop (start trigger → init → signal trigger speed sensor → measure grid 100–300 RPM with statistical analysis, speed output and target speed detection → store) → end; error flow present.
-
Signal Statistics
Characteristic block per grid point.
Characteristic start → mean value (AVG) → FFT → characteristic end.
Inside the software
Take it with you
Import through the SonicTC DbManager — individually or merged into an existing database.
Ready to experience acoustic test technology in your line?
Send us your part or schedule an online demo. First assessment within 24 hours.